3 refrigerant changes to flag on a service dispatch ticket

WrenchQuarry Editorial Team · Published · 15 min read · How these guides are written

Flag three refrigerant changes on every dispatch ticket: R-410A is being phased out across the United States, A2L is becoming the dominant refrigerant in HVACR equipment, and A2L can be extremely harmful to anyone who handles it without proper training. These changes affect what the tech needs before arriving, so the ticket should name the refrigerant and whether the assigned tech is trained to work with it.

Net takeaways

  • The phase-out of R-410A is under way across the United States, and it will be replaced by a new class of refrigerants (ACCA).
  • A2L will become the dominant refrigerant used in HVACR equipment (ACCA).
  • A2L can be extremely harmful to those who handle it without proper training, so tickets should flag the refrigerant before a tech rolls (ACCA).
  • The changes are part of a transition to next-generation refrigerants tied to the Kigali Amendment and the American Innovation and Manufacturing (AIM) Act of 2020 (AHRI).

Why R-410A is the first refrigerant to flag

R-410A comes first because its phase-out is happening now. ACCA's A2L training page states that R-410A "is being phased out across the United States and will be replaced by a new class of refrigerants." That sentence holds two facts a dispatcher can act on. The first is that the phase-out is under way across the country, so an R-410A system should not be treated as a routine call handled the way it always was. The second is that the replacement is a new class of refrigerants, not a like-for-like swap, so the customer's system may need a different approach than the one the tech expects.

The practical step is to read the refrigerant type from the customer's description before assigning the job. Many callers know the brand and age of their equipment but not the refrigerant, so the dispatcher may need to ask one or two specific questions, such as whether the unit's nameplate lists R-410A. If the answer is yes, the ticket should carry that fact in plain words. A ticket that says only "AC not cooling" leaves the tech to discover the refrigerant on site, and that discovery costs time at the condenser or in the mechanical room.

The flag also protects the schedule. A tech who arrives knowing the refrigerant can bring the right tools, handling procedures, and parts. A tech who finds out on site may need to leave and return, and the customer waits longer. For a dispatcher, the rule is simple: if the system uses R-410A, the ticket says so in the first line the tech will see before loading the truck.

Reclaimed ODS and HFC volumes side by side

The EPA's reclamation trends summary tracks two groups of refrigerants. Its visualizations show the amount of reclaimed ozone-depleting substances (ODS) used as refrigerants, and starting in 2017, the amount of reclaimed hydrofluorocarbons (HFCs) used as refrigerants. The table sets the two groups side by side and adds the two HFCs the EPA identifies as most widely used.

Refrigerant groupHow EPA reports itWhat the EPA says about it
ODS (ozone-depleting substances)Reclaimed volume shown in EPA visualizationsTracked in the same visualizations as HFCs
HFCs overallReclaimed volume shown starting in 2017Approximately 10 percent increase in 2025 compared to 2024
R-410ANamed as a most widely used HFCMain driver of the large year-over-year increase in HFC reclamation
HFC-134aNamed as a most widely used HFCMain driver of the large year-over-year increase in HFC reclamation

R-410A and HFC-134a are the two HFCs the EPA names as most widely used in refrigeration and air conditioning.

The distinction matters because the EPA data shows where recovered refrigerant volumes are concentrated. HFC reclamation is the category that has grown, and the growth traces back to R-410A and HFC-134a, the two HFCs the EPA names as the main drivers. A dispatcher who sorts tickets by refrigerant group can see the workload pattern before the tech arrives, which makes scheduling and parts planning more accurate.

Reclamation of HFCs rose about 10 percent in 2025

The newest figure in the EPA data is the 2025 change. The same EPA summary reports that "in 2025, the data reported to EPA show an increase of approximately 10 percent in the total volume of HFCs reclaimed compared to 2024." That is a single year-over-year comparison, and it applies to total HFC volume, not to any one refrigerant. The table breaks the comparison into its parts.

MeasureFigure from the EPA summary
Total HFC volume reclaimed, 2025Approximately 10 percent higher than 2024
Total HFC volume reclaimed, 2024Base year for the comparison
Direction of change, 2025 over 2024Increase

A ticket involving an HFC system is more likely to need the recovery and handling steps that come with reclaiming refrigerant, so the dispatcher should note the refrigerant type early. The figure also gives the office a reason to review its own ticket history. If a shop logged more HFC calls in 2025 than in 2024, the EPA trend matches what the office sees on its own board.

The increase is not a reason to change every ticket. It is a reason to make the refrigerant field mandatory, so a dispatcher never has to guess whether a call involves an HFC system. A short field with the refrigerant name and its group gives the tech what recovery planning requires, and it gives the owner data to compare year over year.

What the A2L shift means for tickets

ACCA's A2L training page makes a direct statement about where the industry is heading: "A2L will now be the dominant refrigerant used in HVACR equipment." Dominant means A2L is expected to be the refrigerant most commonly used in HVACR equipment, which moves it from a specialty item into an everyday part of the call mix. A dispatcher who treats A2L as an exception will be surprised more often as the transition continues.

The practical response is to build A2L into the standard ticket. Instead of asking whether a call involves A2L, the dispatcher should ask for the refrigerant on every HVACR call and record the answer in the same field. Once A2L is the expected refrigerant, a blank refrigerant field becomes a risk, because the tech may arrive without knowing which handling practices apply. A consistent field also shows when A2L calls are rising in the shop's territory.

The change also affects how work is assigned. Because A2L will be common, the shop should plan for A2L calls as part of normal scheduling rather than something a single senior tech handles. The dispatcher should base the plan on the calls the shop already receives. A2L belongs on tickets as routinely as the system type and the customer's address.

How untrained handling creates risk

The most important word in the ACCA statement is the qualifier. ACCA says that "A2L can be extremely harmful to those handling it if they are not properly trained." The risk depends on the person handling the refrigerant and their training, not only on the refrigerant itself. A dispatcher who sends an untrained tech to an A2L system has created the hazard, even if that tech is experienced with other refrigerants.

That means training status belongs on the ticket. Before assigning an A2L job, the dispatcher should confirm that the assigned tech has the training needed for A2L handling. This is a check on people, not equipment. A shop that keeps a current list of which techs are trained on which refrigerants can match jobs to people quickly, while a shop without that list depends on memory.

Assignment is where most of this risk can be prevented. Once a tech has left for a job, the dispatcher has little control over handling. A simple rule helps: if the ticket shows an A2L system and the assigned tech is not trained for it, the dispatcher reassigns the job before the tech rolls. The ticket should record the reassignment so the owner can see the decision later, which also supports the shop's training plan.

What incorrect A2L handling can cause

The ACCA training page names three outcomes of poor handling. In its words, "if handled incorrectly, A2L can cause suffocation, fire, or property damage in the field." Those outcomes are the reason the ticket has to carry the refrigerant name, not just a general note that the call is an AC job.

The three outcomes reach different people. Suffocation is a risk to people in the space where the work happens, including the tech and anyone in the home or building who is still nearby. Fire and property damage reach past the tech to the structure, its contents, and the people around it. A dispatcher does not need to understand the chemistry to see that spread. The ticket should note the type of space, such as an enclosed mechanical room, a basement, or a rooftop unit, because the tech needs that detail to plan access and decide whether the job can be done safely as scheduled.

The phrase "in the field" matters too. ACCA is describing what happens during work at the customer's site, not in a shop or training room. That means the decisions that reduce risk are made before the tech arrives. Once the tech is at the unit, the dispatcher cannot change the outcome. The moment that counts is assignment and ticketing: the refrigerant is named, the space is described, and the assigned tech is checked against the training ACCA describes as necessary.

A short risk line on the ticket can hold all of this. It might list the refrigerant type, the space type, whether occupants are present, and whether a trained tech has been confirmed. Those items take little time to enter. They give the tech a clear starting point on arrival and give the owner a record if the job ever needs review. The line also makes it harder for a call to go out with a blank field that nobody noticed.

The transition behind the change

The AHRI page on the safe refrigerant transition gives the larger reason behind the changes on the ticket. It states that "the HVACR and water heating industry is implementing a transition to next-generation refrigerants with the Kigali Amendment to the Montreal Protocol and the American Innovation and Manufacturing (AIM) Act of 2020." The sentence names two frameworks and describes an industry-wide implementation, not a single product swap.

For a dispatcher, the useful reading is that these changes are connected. The R-410A phase-out and the rise of A2L as the dominant refrigerant are parts of one shift toward next-generation refrigerants; the growth in reclaimed HFC volumes is a separate pattern an editor can read alongside it. When the office sees that pattern, it can stop treating each new refrigerant as a surprise and make the refrigerant field a permanent part of every HVACR ticket.

The AHRI statement names two equipment groups: HVACR and water heating. A call may involve a water heater as easily as an air conditioner, and the refrigerant question applies to both. An intake form that asks only about cooling systems will miss calls that belong in the same workflow. The form should ask for equipment type first, then refrigerant, for any HVACR or water heating call.

The quoted sentence also has limits. It does not list which products change first or set a date for each one, and the dispatcher should not fill that gap with guesses. The ticket should record what the equipment and the caller can confirm. When the office needs a timeline for planning, it should check the current source directly rather than rely on memory or on what a supplier mentions on a phone call.

Track figures in office reports

Two figures are worth tracking, though they belong in office reports rather than on each job. The first comes from the EPA reclamation summary, which reports that "in 2025, the data reported to EPA show an increase of approximately 10 percent in the total volume of HFCs reclaimed compared to 2024." The second is the 2020 date in the name of the AIM Act, which the AHRI page cites as part of the transition framework.

FigureValue in the sourcesHow the office can use it
HFC reclamation changeApproximately 10 percent increase, 2025 over 2024Compare the shop's own HFC call counts for the same two years
Base year for the comparison2024Starting point for the shop's year-over-year tally
AIM Act date2020Context for the transition, not a ticket field

The 10 percent figure describes total HFC volume reclaimed in the EPA's data. It does not describe any single shop, and it cannot predict how many calls the office will get next year. Treat it as a signal that HFC recovery work is growing, and let the shop's own records answer the local question. Its real value is the discipline it supports. Tagging each ticket with a refrigerant name and group creates the data the owner needs to see whether the shop's HFC work follows the same pattern.

The 2020 date works differently. It helps the team explain why the refrigerant field changed, which matters when a tech asks why a new question appears on the intake form. A brief explanation at the training meeting, citing the AIM Act and the Kigali Amendment, gives context without turning the ticket into a history lesson.

Dispatch steps before a tech rolls

These steps use the EPA and ACCA facts most relevant to the ticket. They run in order: steps 1 to 3 at intake, then steps 4 and 5 at assignment and hand-off.

  1. Get the refrigerant name. Ask the caller for the nameplate reading or the refrigerant listed on the unit. If the nameplate shows R-410A, record it. The ACCA training page states that R-410A "is being phased out across the United States and will be replaced by a new class of refrigerants," so an R-410A call should be marked as a transition case from the start.
  2. Sort the group. Using the EPA summary, record whether the refrigerant belongs to the ozone-depleting substance group or the HFC group. The EPA tracks reclaimed ODS in its visualizations and, starting in 2017, reclaimed HFCs.
  3. Flag A2L when it appears. If the unit uses A2L, add the risk line described earlier and check the assigned tech's training before dispatch.
  4. Match the tech. Assign only techs whose training covers the refrigerant on the ticket. If no tech qualifies, the job waits rather than rolling with an unqualified tech.
  5. Hand off the note. The tech should see the refrigerant name, the group, the space type, and the training check on the first screen of the job, before loading the truck.

Ticket fields that show the refrigerant

A ticket needs a small set of fields that show the refrigerant clearly. The EPA summary names R-410A and HFC-134a as the two most widely used HFCs for refrigeration and air conditioning, and identifies them as the main drivers of the large year-over-year increase in HFC reclamation. Those two names belong in the refrigerant field's drop-down list, so the dispatcher can select them without typing.

FieldWhat to enterWhy it matters
Refrigerant nameR-410A, HFC-134a, A2L, or the name on the nameplateTech knows the handling path before arrival
Refrigerant groupODS or HFCMatches the EPA's two reporting groups
Equipment typeHVACR or water heatingCovers the sectors named in the AHRI transition statement
Transition noteYes or no, for R-410A and new-class replacementsMarks calls under the phase-out
Training matchTech name and trained statusConfirms a qualified tech is assigned

The AHRI page describes a transition to next-generation refrigerants, so the refrigerant field should not be a fixed list. The drop-down should allow new names as they appear. A free-text option next to the list lets the dispatcher enter something the list does not yet include, and the owner can add it to the list later.

Keep the form short. A handful of fields covers most calls. Long forms get skipped under pressure, and a skipped refrigerant field is exactly the failure this post is meant to prevent. If the refrigerant field is blank at intake, the dispatcher should hold the job until someone fills it in.

Related guides: 5 Atlassian flow limits to check for a dispatch queue · Avoidable truck rolls: 3 dispatch mistakes to fix · Check 5 guardrail and toeboard limits before dispatch.

Questions readers ask

Does EPA reclamation data cover older refrigerants too?

The EPA reclamation trends summary shows reclaimed ozone-depleting substances (ODS) used as refrigerants in its visualizations. Starting in 2017, the same visualizations also show reclaimed hydrofluorocarbons (HFCs) used as refrigerants. A comparison of HFC volumes should therefore begin with 2017, because the HFC data starts in that year.

Does the 10 percent increase apply to one refrigerant?

The EPA summary reports that in 2025 the data show an increase of approximately 10 percent in the total volume of HFCs reclaimed compared to 2024. That figure describes the total across HFCs, not any single refrigerant. It does not by itself tell you whether one refrigerant's reclaimed volume rose or fell.

What is driving the big jump in HFC reclamation?

The EPA summary names R-410A and HFC-134a as the main drivers of the large year-over-year increase in HFC reclamation. It also says these two are currently the most widely used HFCs for refrigeration and air conditioning.

What is happening to R-410A in the United States?

The ACCA A2L training page states that R-410A "is being phased out across the United States and will be replaced by a new class of refrigerants." The replacement is described as a new class of refrigerants, not a single named product, so a technician should not assume a like-for-like swap.

Will A2L remain a specialty refrigerant?

No. ACCA states that "A2L will now be the dominant refrigerant used in HVACR equipment." Dominant means A2L is expected to be the refrigerant most commonly found in HVACR equipment, so it moves from a specialty item to routine work. Scheduling, training, and ticket fields should treat A2L as a normal part of the call mix.

Does an experienced tech still need A2L training?

The ACCA page says A2L "can be extremely harmful to those handling it if they are not properly trained." The page ties the risk to proper training for A2L specifically. It does not say that general experience with other refrigerants replaces that training. Dispatchers should confirm A2L training for the assigned tech rather than assume general HVACR experience is enough.

Is A2L only a fire hazard?

No. The ACCA page lists three outcomes of incorrect handling: "suffocation, fire, or property damage in the field." Fire is one of those three, alongside suffocation and property damage. The page does not rank them or say which is most likely, so a ticket note should cover the full set rather than treating fire as the only concern.