- Base distance: one quarter of the working length from the feet to the top support, giving a 75-degree lean
- Top extension: at least 1 metre (3 ft) above the landing platform so the climber has a handhold stepping off
- Power line clearance: at least 10 feet
- Height trigger: at 3 metres (10 feet) or higher, a fall protection program may be necessary
- Extension ladders are not self-supporting — the structure behind them must carry the load
Set the base a quarter of the working length from the support, and extend the top at least one metre above the landing. With 10 feet of clearance from power lines, these are the three numbers to check before the tech climbs.
Key takeaways
Who this is for
You dispatch the job. You write the notes. And then someone you trust carries an extension ladder across a parking lot, leans it against a wall, and climbs it to a rooftop unit. You are not on that ladder. The three numbers in this post are the ones you can check from the ground, before the tech leaves the shop, and again when they call in.
If you run service calls, attics, and roof access off the same dispatch board, the ladder setup is a scheduling question as much as a safety one. A wrong setup turns a quick call into a two-hour call, or worse. The rest of this post walks the three numbers in the order your tech will meet them: the base, the top, and everything around the ladder.
The setup at a glance
Here is the setup in one table, so you can print it and pin it by the dispatch desk.
| Setup point | Number | Source |
|---|---|---|
| Base distance from support | 1/4 of working length | CCOHS |
| Resulting lean angle | 75 degrees from the ground | CCOHS |
| Top above a landing platform | 1 m (3 ft) minimum | CCOHS |
| Clearing power lines | 10 feet | CCOHS |
| Fall protection threshold | 3 metres (10 feet) or more | CCOHS |
The working length is the distance along the side rail from the top support down to the bottom of the ladder. It is not the full ladder length when the sections are closed. Your tech measures the part that is actually in use once the ladder is set.
Number one: where the feet sit
The base distance decides the lean. Put the horizontal distance between the feet and the top support at one quarter of the working length, and the ladder leans at 75 degrees from the ground. That is the geometry that keeps the ladder steady under load without wanting to kick out or slide down the wall.
Tell your tech to pace it out rather than eyeball it. A common working length on a service ladder puts the feet a couple of paces back from the wall. The exact pace depends on the ladder, so the rule is the fraction, not the paces.
Two things follow from that base position.
First, the ladder needs a firm, level surface with secure footing. A ladder set on gravel, soft mulch, or a sloped parking bumper will creep as soon as weight goes on it. If the ground will not hold, the setup is wrong before anyone climbs.
Second, the ladder is not self-supporting. It needs a stable structure behind it that can take the intended load. Leaning an extension ladder against a weak parapet, a rotten soffit, or an unsecured HVAC curb is a different failure than bad geometry, and the base number does not save you from it.
Section order matters
Set the upper section so it rests in front of the bottom section. That is the direction that keeps the fly section from sliding down under the climber's weight. If a tech sets the ladder the other way round, the section can slip regardless of how good the base angle looks.
When you write the job note, ask for a photo of the set ladder before the climb. You can check the base distance and the section order from the picture without standing there.
Number two: how far the top extends
For access to an elevated work surface, the ladder needs to extend at least one metre, or 3 feet, above a landing platform. That extra rail is what the climber holds while stepping from the rungs onto the roof, the platform, or the attic hatch.
A ladder that stops flush with the roof edge forces a reach-and-swing move at the exact moment both hands and feet are committed. It is a risky move at the step-off. Ask for the metre every time, even when the ladder in the van feels long enough.
Two constraints sit alongside that extension.
Double cleat ladders cannot exceed 24 feet in length. California's ladder and stairway rules set that ceiling, so if you are specifying equipment that will be used on jobs under that jurisdiction, check the length before it leaves the yard. The rule is on the California Department of Industrial Relations page.
And at 3 metres (10 feet) or higher, a fall protection program may be necessary. Decide before dispatch whether the job carries a program, not after the tech is standing at the base looking up. For the checks that go with that decision, see Fall protection checks: 8 points before dispatch.
Number three: what is around the ladder
The base and the top are geometry. The third number is clearance.
Keep ladders and other tools at least 10 feet away from power lines.
The line may not be the one you expect. Put the clearance note in the dispatch record when the job address has overhead service. For a fuller list of line checks, see Overhead line checks: 8 items before dispatch.
Fall protection is what you do to eliminate fall hazards, prevent falls, and make sure anyone who does fall survives it. That is the framing Oregon Occupational Safety and Health puts on the topic, and it is the right one for a ladder setup: the setup either removes the hazard or it does not.
A roofing supervisor died after falling 30 feet through a warehouse roof skylight. Oregon OSHA published the account on the same page. Your techs can meet a similar hazard when they step from the ladder onto the roof surface, which is why the top extension and the fall protection decision belong in the same job note.
What to put in the dispatch note
Base: working length, quarter-distance pacing, firm level ground, footing secure.
Top: one metre above the landing point, upper section in front of lower section.
Clearance: 10 feet from power lines, confirm on approach as well as at set-up.
Height decision: is the work surface 3 metres (10 feet) or higher, and does that trigger a fall protection program for this job?
Roof condition: skylights, hatches, and soft spots near the ladder landing point.
That last line is not one of the three numbers. It is the note that keeps the ladder job from becoming a roof job. The ladder was never the only hazard on the call. For the full handoff, use the Field Service Work Order Checklist for Dispatch Handoffs.
How to check the setup from the office
You cannot measure a ladder from a desk. You can check whether the person climbing it was given the three numbers before they left.
Ask the tech for a photo of the set ladder before the first climb. You will see the base distance, whether the feet are on firm ground, and whether the upper section sits in front of the lower one. Ask whether the top clears the landing by a rail, not by an inch.
Ask one question about the surroundings: what is above the ladder, and what is behind it. The answers cover power lines and the supporting structure in two sentences.
If the photo or the answers come back wrong, call before the climb, not after. A callback on a ladder setup costs less than a callback on a fall.
The parts people get wrong
Setting the ladder by eye. A ladder that looks right from ten feet away can be several inches off the quarter-distance. Off-angle ladders creep under load, and creep is what turns a steady climb into a slide.
Ignoring the ground. Firm and level is not a preference. A ladder on a soft or sloped surface loses its base angle the moment weight goes on it, no matter how carefully the top was placed.
Stopping the top at the roof edge. No rail above the landing means no handhold at the step-off. It is a common version of this error, and the one a photo catches fastest.
Wrong section order. Upper section behind lower section allows the fly to slip. The check is visible from the ground.
Carrying the ladder near lines. A tech who sets the ladder perfectly can still foul a line walking it across the yard.
Treating height as a guess. If the work surface is at 3 metres (10 feet) or higher, that is the trigger for considering a fall protection program. Decide before dispatch.
Related guides: Portable ladder setup: 3 figures to check before dispatch · Site setup: 6 wall, opening, rail, ladder, shade, toilet · California paid sick leave: 4 numbers for part-time techs.
FAQ
What is the one number to check if you can only check one?
The base distance: one quarter of the working length between the feet and the top support. It sets the lean at 75 degrees from the ground, and every other part of the setup assumes it. A wrong base makes the top extension and the roof step-off worse.
Does the 3-foot top extension apply to attics and hatches too?
Yes, when the hatch opens onto a landing platform. The rule is written for access to an elevated work surface, with the ladder extending a minimum of 1 metre, or 3 feet, above a landing platform. An attic hatch with a platform at the opening falls under that. A hatch you climb straight through without a landing is a different case, and your safety lead should confirm how you treat it.
When does a ladder job need a fall protection program?
At 3 metres, or 10 feet, or more above ground, a fall protection program may be necessary. Whether the program is required for your specific job is a call for your safety lead, not something the ladder setup itself decides.
Can a tech just use a taller ladder instead of setting one properly?
No. The base distance is a fraction of the working length, so it scales with ladder size. A longer ladder set at the same visual distance as a shorter one is off-angle. The number moves with the equipment.
What about power lines on the roof itself, not just at the base?
The 10-foot clearance applies to ladders and other tools around power lines, wherever they run. Service drops and rooftop connections count. Have the tech walk the roof approach before setting the ladder if lines are present.
Who decides whether a particular job carries fall protection?
Your safety lead, using the job's height and conditions. The ladder setup gives them the height decision, at 3 metres (10 feet) or higher, and the site conditions. Oregon OSHA's framing is useful here: fall protection is what you do to eliminate the hazard, prevent the fall, and make sure a fall is survivable.
What if the ground at the set-up point will not hold?
Then the setup is not valid and the job waits for a fix — cribbing, a different access point, or a different approach entirely. Placing ladders on a firm, level surface with secure footing is a precondition, not a step you can skip when the site is awkward.
How long should a ladder setup take to check?
Long enough to pace the base, confirm the top clears the landing, and scan for lines. If a photo of the set ladder arrives before the first climb, the office check is a glance. The cost of the check is measured in seconds; the cost of skipping it is not.