The first rule deals with open flames and sparks. The Washington rule says Category 1, 2, or 3 flammable liquids may be used only "where there are no open flames or other sources of ignition within 50 feet of the operation, unless conditions warrant greater clearance" (WAC 296-155-270).
Three parts of that sentence matter on a real job. First, the 50 feet is measured from the operation, the spot where the liquid is used or poured, not from the building's front door. Second, the words "other sources of ignition" reach further than an open flame. Pilot lights, brazing torches, hot surfaces, and electrical equipment that can spark all belong in the check. Decide what counts before the job starts, not halfway through it. Third, the phrase "unless conditions warrant greater clearance" makes 50 feet a minimum, not a target. A small room, poor airflow, or a work spot near a vent is a reason to add distance.
In practice, walk the path from where you open the cleaner to the nearest flame, spark, or hot surface. If the closest one is inside 50 feet, move either the work or the source before you start. Do not assume a torch is harmless because it is "only for a minute." The rule does not care how long the flame runs.