Straight into the service manual page
WrenchQuarry
More

Wildfire smoke exposure: 3 control levels below AQI 151

WrenchQuarry Editorial Team · Published · 13 min read · How these guides are written

In California, keep crew smoke exposure below AQI 151 by fixing the air first, then the schedule and location, with respirators as a supplement. That order comes from California Code of Regulations, Title 8, Section 5141.1; other jurisdictions may set different rules. The whole system starts with a reading taken at your worksite.

Key takeaways

  • Measure the air at the worksite, not across town, and convert that reading to AQI before you make the day's call.
  • Engineering controls come first: enclosed buildings, structures or vehicles with filtered air.
  • Administrative controls come next: relocate the work, change the schedule, cut work intensity, add rest.
  • Respirators enter the picture at an AQI at or above 151 and up to 500, for voluntary use.
  • A respirator is a supplement to the first two levels, never a replacement for them.

What the AQI 151 line actually means on your worksite

Wildfire smoke is mostly fine particulate matter. You cannot see most of it, and your lungs cannot filter it. On a smoke day, your job is to keep the air your crew breathes below a reading of 151 on the Air Quality Index for PM2.5. In California, that number is a line set by regulation, not a comfort preference.

The California Department of Industrial Relations publishes California Code of Regulations, Title 8, Section 5141.1, Protection from Wildfire Smoke, which applies to California worksites. It places several duties on the employer, and the controls it names must be applied in a set order.

That order is the whole system. You reach for engineering controls first, meaning you fix the air. When engineering controls are not enough or not possible, you reach for administrative controls, meaning you fix the schedule and the location.

This post walks each level in that order. It is written for owners, dispatchers and team leads who need to make a call before the trucks roll.

TL;DR: Measure PM2.5 at your worksite and convert it to AQI. Below the line, work as normal. At or above 151, bring in filtered space first. If filtered space does not get you under the line, move the work, change the hours and slow the pace. Between 151 and 500, supply N95-class respirators for voluntary use and encourage your crew to wear them.


How the three levels fit together

The regulation does not offer a menu. It offers a ladder. You climb it in order, and you can only skip a rung when that rung is genuinely unavailable to you on that site, on that day.

Level one: engineering controls. You reduce exposure by changing the environment. Filtered air in an enclosed space is the example the rule gives. If you can put a truck cab or a job trailer between your crew and the smoke, that is your first move.

Level two: administrative controls. You reduce exposure by changing what people do and where they do it. You move the task, shift the clock, lower the pace, or hand out extra breaks. This level matters most on sites where nothing enclosed exists, or where the enclosed space is too small for the whole crew.

Level three: respiratory protection. You give the crew something to wear while levels one and two do their work. The rule triggers this at an AQI of 151 or higher and does not exceed 500.

The three levels are not alternatives to each other. A dispatcher running all three at once is doing the job correctly. A site lead running only respirators is not.

Here is the thing most people miss on a smoke day. The measurement itself is part of your control system. You have to know the number at your worksite before you can pick a level. The rule puts the duty squarely on the employer: measure PM2.5 levels at the worksite and convert the PM2.5 levels to the corresponding AQI in accordance with Appendix A.

That word "worksite" matters. An AQI reading from the nearest city, a regional dashboard, or the county alert system is background information. It tells you a smoke event is real. It does not tell you what the air is doing where your crew stands, which can differ because of terrain, buildings, wind and distance from the fire.

Build a habit: someone on your team pulls a reading at the site, at the start of the shift, and again if conditions shift. Log it with the time. That log is your evidence later that you made decisions on facts, not on a gut feeling.


The three control levels side by side

Here is the ladder laid out plainly so you can print it and hand it to a team lead.

Control levelWhat it looks like on siteWhen it applies
EngineeringEnclosed buildings, structures, or vehicles with filtered airFirst choice, always, whenever feasible
AdministrativeRelocate work, change work schedule, reduce work intensity, more restWhen engineering controls are not feasible or do not get you under 151
RespiratoryNIOSH-approved respirators, such as N95 filtering facepieces, for voluntary useWhen AQI is at or above 151 and does not exceed 500

All three cells carry rules. The engineering cell applies whenever it is feasible for you. The administrative cell applies when engineering controls are either impossible or simply not enough to drop the reading under the line. The respiratory cell applies across a defined band of the index, which gives you a clear trigger.


Level one: bring the air down with engineering controls

Start here because the regulation starts here, and because it reduces the contaminant in the space your crew occupies directly.

The rule says it plainly: the employer shall reduce employee exposure to PM2.5 to less than a current AQI of 151 by engineering controls whenever feasible, for instance by providing enclosed buildings, structures, or vehicles where the air is filtered.

Read the words "whenever feasible" carefully. Feasible does not mean easy. A job trailer with a working HVAC system and clean filters is feasible. A bare concrete pad with no structure anywhere on the block is not.

What engineering controls look like in practice on a construction or field site:

  • A job trailer or office container with the air recirculated through a filter.
  • A truck cab with windows up and the ventilation set to recirculate rather than fresh-air intake.
  • A break room or enclosed staging area where the crew eats and rests between tasks.
  • Any structure you can seal well enough that the air inside it is measurably cleaner than the air outside.

The last point is the one that separates a real control from a gesture. Put a meter inside the space and compare. If the reading inside the cab is not lower than the reading outside, you have a break area, not an engineering control. Re-test after you change filters or close doors.

Capacity is the practical limit. A site with one trailer and a crew of twenty cannot move everyone inside at once. That is a scheduling problem you solve at level two, by rotating crews through the clean space. It is still an engineering control doing the heavy lifting; the rotation just manages access.

Enclosure also fails on some tasks. A roofer cannot work inside a cab. A demolition crew cannot relocate into an office. On those jobs, engineering controls may be limited to rest and transition periods rather than the full work shift. In that case, level one does the part it can do, and levels two and three carry the rest of the load.

Track your engineering controls the same way you track other site equipment. Know what you have, where it is, what condition it is in, and whether the filters are current. A filtered space with a saturated filter is not a filtered space.


Level two: move the work, the clock, or the pace

When engineering controls cannot get your crew under the line, you move to the next level. This is where most of the day-to-day decisions of a dispatcher live.

The rule gives you the sequence: whenever engineering controls are not feasible or do not reduce employee exposures to PM2.5 to less than a current AQI of 151, the employer shall implement administrative controls, if practicable, such as relocating work to a location where the current AQI for PM2.5 is lower, changing work schedules, reducing work intensity, or providing additional rest periods.

Four levers, in the order the rule lists them:

Relocate the work. Smoke is not uniform across a region. A valley that sits under a plume all afternoon may clear by morning, or the far side of a county may read much lower at the same hour. Where your project allows it, move the task to the better air.

Change the work schedule. This is the lever most dispatchers already use instinctively. Move heavy outdoor work to the hours when the reading drops. Push interior or filtered tasks into the worst window. Shift the whole crew earlier or later in the day.

Reduce work intensity. A task done at a hard pace moves more air in and out of the lungs than the same task done steadily. On a smoke day, ask for the same output over more time rather than the same time with more strain.

Provide additional rest periods. More breaks, longer breaks, or breaks inside filtered space. Each one cuts the volume of smoke-laden air a worker takes in over the shift. For break timing rules that apply to crews, see meal and rest break limits for crews.

The fourth lever is the easiest to shorten when the schedule slips. Resist that. Rest periods on a smoke day cut how much smoke each worker breathes in, but they do not lower the air concentration the way filtration does. Cutting them quietly raises exposure back up without changing any reading you logged at the start of the shift.

Administrative controls also have a failure mode worth naming. They work when someone is watching the clock and the meter. A plan written in the morning and ignored by mid-afternoon controls nothing. Assign the responsibility to a named person on every shift, the same way you would assign a fire watch or a spotter.

Ask your state's workplace safety regulator which instruments and methods they expect you to use to take that reading.


Level three: respirators when the index sits high

Respirators are the third layer. They protect the person wearing them. They do nothing for the air around them, and they do not excuse you from running levels one and two. For the ventilation side of this, see respirator rules when ventilation falls short.

The trigger is specific: where the current AQI for PM2.5 is equal to or greater than 151, but does not exceed 500, the employer shall provide a sufficient number of respirators to all employees for voluntary use in accordance with section 5144 and encourage employees to use respirators.

Two words in that sentence carry weight. "Sufficient number" means you plan your stock before the day, not after the first crew asks. "Voluntary use" means you supply and encourage. You cannot order a worker to wear one under this provision, which makes the quality and comfort of what you stock matter more than it would under a mandatory program.

The equipment standard is clear: respirators shall be NIOSH-approved devices that effectively protect the wearers from inhalation of PM2.5, such as N95 filtering facepiece respirators.

Practical points that decide whether your stock actually gets used:

  • Stock the size range your crew actually needs. A facepiece that leaks at the seal protects nobody.
  • Keep them where the work happens. A box in a locked office is not available on the deck.
  • Pair supply with a short demonstration. A respirator worn loosely under the chin does nothing.
  • Track the band. At or above 151 and up to 500, supply and encourage, and keep your log current through the day.

An N95 filtering facepiece is the reference example the rule gives, so check that model first when you count stock.


Building the day: how a dispatcher actually runs this

What follows is how the three levels work together on a live shift.

Your morning starts with a reading at the worksite. Convert it to AQI. If the number sits comfortably below the line, you run the day as planned and keep an eye on it. If it has crossed, you open the ladder. Pair this with job site dispatch checks before crews leave so the reading is in hand before anyone leaves the yard.

First, you inventory what enclosed, filtered space exists. Who can work inside the trailer today, and for how long? What tasks must happen outdoors regardless? That gives you the shape of the day.

Second, you set the rotation. Crews cycle through the clean space for breaks and rest periods. Outdoor tasks get scheduled into the windows where the reading is lowest. Work that can move to a better-air location moves.

Third, you check the cabinet. If your reading is in the band that calls for respirators, you confirm supply is on site, sizes are covered, and someone has shown the newer hands how to wear one properly.

Fourth, you assign ownership. Each shift needs one named person who owns the log, the rotation and the rest schedule. Write it on the board where the crew can see it.

Throughout the day, re-read. Smoke moves. A reading taken at six in the morning describes six in the morning. Conditions at mid-afternoon deserve their own reading and, if the number has moved, their own set of decisions.

At the end of the shift, file the readings with the day's records. You want to be able to show, in your own handwriting, what the air was doing and what you did about it.


What good looks like on a smoke day

The goal is not a perfect site. On a heavy smoke day, no plan makes outdoor air clean. The goal is that every hour of exposure was met with a control, in the right order, chosen on a reading taken at your site.

A crew lead who checks the index, rotates people through the trailer, pushes the heaviest task to the cooler hours, and hands out respirators without being asked is running all three levels correctly. A site where the only response is a box of masks on the tailgate is running one level and hoping.

The ladder also protects you from the most common failure on smoke days, which is drift. Without a fixed order, teams reach for whatever is closest at hand. Usually that is the respirator box, because it is visible and cheap. The structured sequence forces the harder, more effective question first: can we change the air itself?

Keep the structure simple enough that a new dispatcher can run it. Measure. Convert. Open the ladder. Assign a name to the day's log. Re-read when conditions shift. File the readings. Six steps, every shift the index crosses the line.

Your next step today: Choose the spot on your site where a reading will be taken at the start of the next shift, and write the time and the number in the log before the crew starts.


Frequently asked questions

What if the reading moves after we have started work? Treat each new reading as its own decision point. Re-evaluate the ladder from the top. If the number has climbed, you may need more rotation through filtered space, a schedule change, or to confirm respirator supply is holding for the rest of the shift. If it has fallen, you can ease controls carefully rather than dropping them all at once.

Do we have to stop work when the index crosses 151? Ask your state regulator about stop-work rules. The regulation requires controls to reduce exposure to less than AQI 151 where feasible, and to the extent feasible where engineering controls are not sufficient. The three levels are your answer to the crossing, applied in order, with a log to show what you did and when.

Is a respirator enough on its own? No. Respirators are the third layer. The rule places engineering and administrative controls ahead of them and expects both to run. A mask on a crew working unfiltered air outside all day is one control out of three.

Who decides whether a control is feasible on our site? The rule leaves feasibility and practicability to the facts of your site. Your state's workplace safety regulator is the right body to ask about how they assess your specific conditions and what documentation they expect to see.

What about the crew inside the trailer? Filtered enclosed space is the engineering control doing the work for them. Keep the doors closed while the outside reading is high, keep the filtration running, and check the inside reading against the outside reading so you know the space is genuinely cleaner.

Sources